Photovoltaic cable - Solar cable
    The Solar cable is produced in conformity with the IMQ CPT-065 IIĀ° Edition 2009 Regulations is suitable for the direct connection to photovoltaic systems, without any additional protective tube for direct laying either in indoor or outdoor installations thanking the technologically-advanced cross-linked elastomeric insulation and special cross-linked sheathing compound .
    SOLAR CABLE 
    CABLE FOR PHOTOVOLTAIC SYSTEMS
    LS0H Low Smoke Zero Halogen & UV resistant
     
    APPLICATION & BASIC CHARACTERISTICS :
     
    The Solar cable is produced in conformity with the IMQ CPT-065 II° Edition 2009, is suitable for the direct connection to photovoltaic systems, without any additional protective tube for direct laying either in indoor or outdoor installations thanking the technologically-advanced cross-linked elastomeric insulation and special cross-linked sheathing compound .
     
    Extraordinary resistance characteristics to the ultraviolet rays (UV), to ozone and other atmospheric agents, to the hydrolysis, the oils, the ammonia, the biogas and to the chemical agents in general.
    The cable is not propagating the flame and in case of fire it releases a low emission of fumes, no toxic and, corrosive gasses (LS0H).
    Materials are in conformity with the RoHS directive (2002/95/CE and the cable make-up is in accordance to the Low Tension Directive (2006/95/CE).
                 
     
      
    CONSTRUCTION:
     
    Wire            :     elementary tin-plate copper wires 5 class according to IEC 60228 CEI 20-29 / VDE 0295
    Insulation   :      cross-linked HEPR/XLPE quality, according to CEI 20-21 (CEI EN 50363) 
    Sheathing     :    cross-linked elastomeric XLPE compound regulations CEI 20-21 (CEI EN 50363)  
     
     
    SPECIFICATIONS:
     
     
    Nominal tension Uo/U…………….…..……0,6/KV c.a. ; 1,5 KV c.c.
    Tension test…………………………….……4000 V, 50Hz
    Electric resistance……………………………Regulations CEI EN 60228 (CEI 20-29)
    Constant of insulation………………………..>750M .. Km a 20 Km a 20° c
    Temperature of  use………………………....-40° C -/- +125°C
    Minimum temperature of laying in work.…...-25°C
    Maximum temperature of short circuit….…...+250° C
    Scheduled duration. ……………………….…>30 years
    Bending radius……………………..…..….…≥ 6 x Ø of cable